Measure current more accurately, more safely, and more reliably
One-sentence selling point: 50A nominal measurement capability, ±0.65% high accuracy, 200kHz wide bandwidth, fully isolated primary-to-secondary – ideal for demanding applications in industrial automation, new energy, and railway traction!
The LA55-P/SP26 is a closed-loop Hall effect current sensor from LEM (Switzerland), designed for applications that demand high precision and high reliability. With a nominal current rating of 50A and a maximum measurement range up to ±70A, it perfectly covers medium-power current detection.
Compared to conventional open-loop Hall sensors, the closed-loop compensation technology delivers a quantum leap:
Accuracy ±0.65% – Even at low currents, measurement errors are kept extremely low, ensuring accurate system control.
Linearity ±0.15% – The output follows the input current with excellent linearity, significantly simplifying system calibration.
Response time 1 µs – Instantaneous output. For fast-response needs such as overcurrent protection and short-circuit detection, 1 µs provides valuable protection headroom.
Bandwidth DC ~ 200kHz – Whether measuring DC, AC power frequency, or high-frequency switching ripple/transients, the LA55-P/SP26 captures them all – especially suitable for switching power supplies, variable frequency drives, and similar high-frequency applications.
What engineers care about most: Closed-loop Hall sensors are largely immune to core saturation and temperature drift. Once calibrated, they need almost no periodic recalibration – a significant maintenance cost saving for largescale deployments.
Electrical isolation between the high-voltage primary side and the low-voltage control circuit is critical. The LA55-P/SP26 works on the Hall effect principle, providing complete galvanic isolation between the primary (power circuit) and secondary (electronic measurement circuit) without any physical contact.
Isolation test voltage 3.6 kVRMS – High withstand voltage, suitable for the severe isolation requirements of industrial and railway traction systems.
UL 94-V0 flame-retardant case – The fully insulated plastic housing meets UL 94-V0, offering excellent flame resistance under high temperature and electrical stress, further enhancing system safety.
Safety value: Isolation not only protects downstream control circuits from high-voltage surges, but also greatly reduces safety risks for commissioning and maintenance personnel.
Conventional shunts (current sense resistors) generate significant insertion loss when measuring large currents. For example, a 50A / 75mV shunt dissipates as much as 3.75W. In modern, high-efficiency power electronics where heat is a concern, every wasted watt hurts system efficiency.
The LA55-P/SP26 uses non-contact Hall measurement:
Zero insertion loss – No additional power consumption in the measured circuit, ideal for low-power designs and highefficiency power systems.
No wear-out mechanism – No contact wear or oxidation over time, providing longer life and reduced maintenance.
|
Parameter |
Value |
|
Brand |
LEM |
|
Model |
LA55-P/SP26 |
|
Sensor type |
Closed-loop Hall effect (compensated) |
|
Nominal current |
50A (bidirectional) |
|
Measurement range |
±70A |
|
Output signal |
Instantaneous current 50mA (ratio 1:1000 / 1:2000 selectable) |
|
Accuracy |
±0.65% |
|
Linearity |
±0.15% |
|
Response time |
1 µs |
|
Bandwidth |
DC ~ 200kHz |
|
Supply voltage |
±12V ~ ±15V |
|
Isolation voltage |
3.6 kVRMS (test voltage) |
|
Operating temperature |
-40℃ ~ +85℃ |
|
Mounting type |
PCB through-hole |
|
Dimensions (W×H) |
36.6mm × 27.6mm |
|
Primary aperture |
12.7mm × 7mm |
|
Case material |
UL 94-V0 flame-etardant plastic |
|
Environmental compliance |
RoHS compliant |
Operating temperature range -40℃ ~ +85℃ – From a northern winter railway yard to a summer outdoor inverter cabinet, the LA55-P/SP26 works reliably.
Low temperature drift – The closed-loop design inherently suppresses temperatureinduced accuracy errors, eliminating the need for additional temperature compensation circuits.
Special note: The SP26 version shares the same excellent temperature stability, making it particularly suitable for industrial sites and railway traction applications where temperature stability is critical.
The LA55-P/SP26 covers many critical fields:
Industrial Automation
Current feedback and closed-loop control of AC variable frequency drives and servo drives
Static converters for DC motor drives
Current monitoring in industrial welding power supplies
Power Supplies & New Energy
Input/output current detection in uninterruptible power supplies (UPS)
Current control and protection in switch-mode power supplies (SMPS)
Current monitoring in solar inverters and wind power converters
Charge/discharge current detection in electric vehicle (EV) battery management systems (BMS) and charging stations
Railway & Traction
Current measurement in railway locomotive traction systems
Current monitoring in metro and rail signal equipment
On-board energy metering systems
Other Applications
Current management in battery-powered equipment
Transient current measurement in laboratory test equipment
Current control and monitoring in air conditioners, elevators, forklifts, etc.
|
Comparison |
LA55-P/SP26 |
Q: I want to work with MacroQuest because of high quality. But I found your price too high and out of line with the prevailing market level, how should I do? Please select the first payment method-Paypal, then you will see Credit Card/Debit Card payment button in the lower right corner. | ||